Time: 2017-02-17
Now, a lot of
The data center
backbone
transmission
All media use super 6
Ethernet cable
, so the requirements are quite high, the need for superior performance.
Integrated wiring
In addition, many large data centers need to design fire protection devices. Therefore, flame retardant super-6 cable is one of the important choices, especially in many developed countries in Europe
CMP
Registration of
Low smoke zero halogen
Materials, and has introduced a number of specifications, such as: the world electrotechnical commission
IEC60332
Series, European Union
EN 50399
and
EN 50265
Series, American
UL
Series.
Data centers tend to have a lot of data
network
Equipment, so the safety aspect is very important, in addition to the safety hazard in the fire particularly prominent, because the data center equipment constantly running, emitting a lot of heat, it is easy to cause a fire. As the main transmission medium, super six types of network cable must exist in large quantities in the computer room of the data center. The use of flame retardant materials as the skin of the super-six network line is many data centers to prevent fire a major method. There are four types of flame retardant materials for making super six types of wire:
1
,
CMX
Low smoke without halogen, this is low smoke without halogen inside grade inside a ****, fire burning time has a certain open fire, but the fire burning up is not very big, the quotation cost is also relatively cheap.
2
,
The CM
Low smoke without halogen, this information is relatively less than the use of contrast, the first is the role is not very significant, burning up a small open fire, network cable quotation is not very cheap, so this information about the occupation is not applicable, just as long as very few
cable
Manufacturers will be willing to use this information to shoddy.
3
,
CMR
Low smoke halogen free, this data contrast is applicable, the first suitable for the straight use, but also everyone loves this data. It is reflected in the burning up for a while since it will calm down, subtle smoke, the role of the contrast is significant, the current is also the domestic and foreign customers love the comparison of this line.
4
,
CMP
Low smoke without halogen, this information is a grade of ****, the first is to use in forced ventilation environment, it reflects no smoke, no light fire, the role is very good, the price is expensive, domestic use is not a lot of, the current primary use in developed countries more.
With the continuous progress of science and technology, the related technology of making super six types of network cable is becoming more and more mature, and its related technical parameters are further optimized. As the transmission medium of the underlying infrastructure of the building, super six type network cable is a kind of flame retardant cable, which emits less toxic gas and acidic gas when burning, and less heat and smoke. The fire safety of buildings, personnel, information and equipment is of vital importance. In addition, the scale of low smoke halogen free super six network cable in China is very small, and its domestic market still needs to be vigorously developed.