国产精品第一区二区三区_欧美A级∨片高潮喷水_精品国产AV一区二区三区久久_欧美AⅤ视频一区二区三区

石家莊煜英新材料科技有限公司
SHIJIAZHUANG YUYING NEW MATERIAL TECHNOLOGY CO. LTD

0311-89299985

News and information

Standard for Combustion Performance of Gansu's Strictest External Wall Thermal Insulation Material

time:
2019-05-13


In order to ensure the fire safety of construction projects and effectively prevent and reduce the fire accidents of building exterior insulation materials, according to the relevant technical standards and the Ministry of Public Security's Notice on the Fire Supervision and Management of Civil Building Exterior insulation materials (Public Consumption [2012] 350) spirit, combined with the actual situation of Gansu Province, Gansu Provincial Housing and Urban-Rural Construction Department and Gansu Provincial Public Security Department jointly formulated recently. And issued a notice on the specification of the combustion performance of building exterior wall insulation materials. The notice requires that ordinary polystyrene panels and extruded panels shall not be used in civil buildings.



According to the spirit of notification, for non-curtain-wall buildings, when the building height is greater than or equal to 50 meters, the burning performance of the exterior wall insulation material should be Grade A; when the building height is greater than or equal to 24 meters and less than 50 meters, the burning performance of the insulation material should not be lower than Grade B1. When grade B1 material is used, fire isolation belts should be installed on each layer. At the same time, non-combustible materials should be used as protective layer. The thickness of protective layer on the first floor of a building should not be less than 10 mm, and other floors should not be less than 5 mm. When the building height is less than 24 meters, the combustion performance of thermal insulation material should not be lower than B1 level. When grade B1 material is used, fire isolation belts should be installed on every two layers. At the same time, non-combustible materials should be used as protective layer. The thickness of protective layer on the first floor of a building should not be less than 10 mm, and other floors should not be less than 5 mm. In hospitals, nursing homes, kindergartens, student dormitories, hotels, shopping malls and places with dense staff, the burning performance of thermal insulation materials should be Grade A. For curtain wall buildings, when the building height is greater than or equal to 24 meters, the combustion performance of thermal insulation materials should be Grade A; when the building height is not greater than 24 meters, the combustion performance of thermal insulation materials should not be lower than Grade B1.



When building exterior wall adopts internal thermal insulation system, it should comply with the following regulations: in evacuation staircases of crowded places and various buildings, the burning performance of thermal insulation materials should be Grade A; in other buildings, places or parts, low smoke, low toxicity and no less than Grade B1 thermal insulation materials should be used. When grade B1 material is used, non-combustible material shall be used as protective layer, and the thickness of protective layer shall not be less than 10 mm. Fire-proof isolation zones shall be made of inorganic thermal insulation materials with a combustion performance of Class A and set along the floor position with a width of not less than 300 mm. Fire-proof isolation belt and basement wall should be fully adhered, and should be constructed at the same time with external wall insulation. In order to ensure the stability and safety of exterior wall thermal insulation materials in use, the smoke toxicity of organic thermal insulation materials should reach the level of quasi-safety ZA1; the water absorption rate of thermal insulation materials should not exceed 4%; and the bulk density of organic or organic modified thermal insulation materials should not exceed 60 kg/cubic meters. It is strictly forbidden to use exterior wall insulation materials that do not meet the current national and Gansu standards or have no product standards.

Previous page:

Flame retardant
Shijiazhuang yuying new material technology co. LTD/

Changchun yinghan new material technology co. LTD

Yinghan link exchangehttp://www.ccyinghan.com

Telephone:0311-89299985   18032822116(Shijiazhuang)    0432- 65077017  13351516123 (Changchun)


Technical support: youdu network
云梦县| 富平县| 石首市| 永宁县| 晋中市| 前郭尔| 台中县| 临邑县| 德格县| 四会市| 读书| 镶黄旗| 岚皋县| 靖西县| 衡东县| 新安县| 巴彦县| 吉林市| 石门县| 五台县| 驻马店市| 迁西县| 昌吉市| 都兰县| 靖州| 六盘水市| 广宗县| 延庆县| 金沙县| 民乐县| 介休市| 新余市| 英吉沙县| 山东省| 合山市| 潢川县| 郁南县| 永年县| 平遥县| 惠来县| 宜城市|